R3-2 Zoning NYC · Fontan Architecture (2024)

R3-2 Zoning is a low density residential zoning district in NYC. You can build single or two family homes as well as small multifamily buildings in R3-2.

The R3-2 Zoning District is a sub district of R3 Zoning in NYC. R3-2 Zoning is mapped in The Bronx, Brooklyn, Queens, and Staten Island. R3-2 is the only R3 zoning where you can develop multi family buildings.

R3 Zoning Districts

  • R3-2

R3 Contextual Districts

  • R3-1
  • R3A
  • R3X

R3-2 Zoning Regulations

The New York City Zoning Resolution is complicated and quite in depth. In this article we will review some basic Zoning Codes with regards to residential zoning district R3-2.This analysis does not assume to cover every possible issue, but provide a general overview of the zoning code.

R3-2 Zoning Community Facility

R3-2 Zoning is a residential zone but Community Facility uses are allowed in R3 zones. In the instance of a community facility the zoning calculations may be different as community facilities have alternate requirements.

R3-2 Zoning Specifications

Minimum Lot Size: Lot Area & Lot Width

Lot Size Single or Two Family Detached:

A Detached house has yards on all sides and does not touch any other buildings or houses.

Minimum Lot width =40 Feet

Minimum Lot Area = 3,800 Sq Ft

Lot Size for Semi-Detached or Attached (single family, two family, or multifamily):

Semi detached houses are built in pairs where they touch in the middle but have yards on the sides. Attached houses touch the property line on both sides or are attached on both sides.

Minimum Lot width =18 Feet

Minimum Lot Area = 1,700 Sq Ft

Lot Coverage & Open Space

Maximum Lot Coverage:35%

The development can not cover more then 35% of the property.

Required Open Space:65%

The development must leave 65% of the property with open space.

R3-2 Floor Area Ratio (FAR):

Floor Area Ratiodetermines the floor area that can be built on the property. The floor area ratio is multiplied by the lot area.

FAR = .5

Attic Allowance 20% bonus

In R3-2 Zoning districts the FAR may be increased by 20% for floor area located under a pitched roof. This is not always possible to achieve.

Density Factor or Dwelling Unit Factor (DU) for R3-2

625 – For Single or Two family detached and semi detached buildings.

870 – For any multifamily buildings, and one or two family attached

R3-2 Building Heights:

Perimeter Wall Height = 21 Feet

Building Height = 35 Feet

Yard Requirements for R3-2

Front Yard = 15 Feet minimum

Rear Yard = 30 Feet

Side Yards Detached = 13 Feet in total with the smaller being 5 feet each

Side Yards Semi Detached = 8 Feet

Multi Family Buildings must have 2 side yards 8 feet wide.

R3-2 Zoning Example

Here is an examplezoning analysis. Be aware that zoning is complicated and I am only addressing the basics here. I assure you there are many additional issues and variations to consider beyond this example.

R3-2 Example Lot

Lets assume we have a 50 foot wide and 100 foot deep property in an R3-2 Zoning District in Queens on an interior lot. We are going to plan to build one multifamily building. A multi-family building is any structure with more than 2 families.

Optional Lot Subdivision

In this example we could potentially divide the lot into two separate lots withalot subdivision. We will not be looking into that in this example.

Zoning Floor Area/ Floor Area Ratio (FAR)

So thefloor area ratiois .5. TheFARis a ratio that determines how many square feet you can build on the property. You simply take the property size and multiply it by theFAR.

In this example we have:

FAR of .5

Lot Size of 50 feet x 100 feet.

Zoning Floor Area = Lot Area X FAR

Lot Area = 50 x 100

Lot Area = 5,000 sq ft

FAR = .5

Zoning Floor Area = 5,000 sq ft x .5

Zoning Floor Area = 3,000 sq ft

There is a zoning Bonus for Attic allowance of up to 20%. Attic allowance is a little complicated, so you will not always be able to maximize the attic allowance. We will assume that we can maximize the attic allowance for the purpose of this example.

Zoning Floor Area with Bonus 3,000 sq ft

So we can build a 3,000 sq ft for each house.

How may families can we have on our R3-2 lot.

Zoning regulates the maximum number of residential units you can put in a building.

R3-2 Zoning Example Conclusion

In this example we are proposing to develop a single 3 family detached building. We will need to provide parking for every family.

R3-2 Zoning in NYC

As an architect I study Zoning Codes closely, but these are complicated and quite involved issues. In this article we reviewed some of the basic concepts with regards to the R3-2 Zoning Districts. This post does not assume to cover every possible issue or condition, but provide a general overview of the topic.

Thank You for reading our post on R3-2 Zoning in NYC.

I hope this was helpful. You can leave questions or comments below. If you want to discuss a specific project with an architect you can contact us directly.

Contact Fontan Architecture

Jorge Fontan

This post was written by Jorge Fontan AIA a Registered Architect and owner of New York City architecture firm Fontan Architecture. Jorge Fontan has earned 3 degrees in the study of architecture including two degrees from the City University of New York and a Masters Degree in Advanced Architectural Design from Columbia University. Jorge has a background in construction and has been practicing architecture for 20 years where he has designed renovations and new developments of various building types.

Related Posts

Home Business Zoning Laws NYC
Density Factor / Dwelling Unit Factor
Converting To Multi Family NYC
R3-2 Zoning NYC · Fontan Architecture (2024)

FAQs

R3-2 Zoning NYC · Fontan Architecture? ›

You can build single or two family homes as well as small multifamily buildings in R3-2. The R3-2 Zoning District is a sub district of R3 Zoning in NYC. R3-2 Zoning is mapped in The Bronx, Brooklyn, Queens, and Staten Island. R3-2 is the only R3 zoning where you can develop multi family buildings.

What is R3 2 zoning in NYC? ›

R3-2 districts are general residence districts that allow a variety of housing types, including low-rise attached houses, small multifamily apartment houses, and detached and semi-detached one- and two-family residences. It is the lowest density zoning district in which multiple dwellings are permitted.

What can be built on R2 zoning near New York, NY? ›

R2 Zoning is a low density residential zoning district in NYC. You can only build single family detached homes in R2 zoning districts. R2 also has subdistricts R2A and R2X which are similar in nature but vary on certain specific regulations.

What are the different types of zoning in NYC? ›

The City is divided into three basic zoning districts: Residential (R), Commercial (C), and Manufacturing (M), which are then further divided into low, medium, and high density districts. There may be different zoning districts within the same neighborhood or city block.

What is R3X zoning in NYC? ›

R3X Zoning is a low density residential zoning contextual district in NYC. You can only build single family or 2 family homes that are detached in R3X. The R3X Zoning District is a contextual sub district of R3 Zoning in NYC. R3X Zoning is mapped in The Bronx, Brooklyn, Queens, and Staten Island.

What is R3 occupancy in NYC? ›

Residential Group R-3 occupancies shall include buildings or portions thereof containing no more than 2 dwelling units, occupied, as a rule, for shelter and sleeping accommodation on a long-term basis for a month or more at a time, and are not classified in Group R-1, R-2 or I.

What is M2 3 zoning in NYC? ›

The M2-3 Zoning District is limited to manufacturing and some commercial uses. The M2-3 Zoning District is a sub district of M2 Zoning in NYC. M2 is a Medium Manufacturing Zoning District having manufacturing and limited commercial uses. M2-3 Zoning is mapped in Manhattan along the East and West Waterfronts.

What does R2 mean in real estate? ›

Medium Density Residential District (R2). The R2 zoning district is intended for areas appropriate for single-family detached homes, secondary residential units, and duplexes.

Can I build a duplex on R2 zoning Central Coast? ›

The following land zonings permit Low Density Residential: R1, R2, R3, R5, RU2, RU6, C3 and C4. This means that subject to council approval you could be able to create a dual occupancy on your site. You'll then need to comply with the DCP requirements for dual occupancies which can be found here.

What is the attic allowance in NYC? ›

An attic allowance is an increase of up to 20 percent in the maximum floor area ratio (FAR) for the provision of a pitched roof.

What are the three most common zoning designations? ›

There are, essentially, three basic zoning categories: residential, commercial, and industrial. Agricultural land is typically the least regulated and usually exists outside municipal boundaries.

What are the three types of zones in a house? ›

Zone types include residential, industrial, and commercial. Property investors should be aware of zoning regulations when purchasing a property so they can plan its long-term development. Zoning plans can be acquired from the local municipality, and estate agents are knowledgeable regarding zoning regulations.

What is R4 zoning in NYC? ›

R4 Zoning is a residential zoning district in NYC that allows for one family and two family as well as small multifamily residential building. You can build detached, semi detached, and attached buildings in R4 Zoning.

What is a predominantly built-up area in NYC? ›

A "predominantly built-up area" is a block entirely within R4 or R5 Districts, including a Commercial District mapped within such Residence Districts, having a maximum area of four acres with buildings on zoning lots comprising 50 percent or more of the area of the block.

What is R2 zoning in NYC? ›

R2 zoning allows for single-family detached homes. The houses are not as large as those in R1 zoning districts, as the minimum land lot width is forty feet wide. The minimum lot area for R2 zones is 3,800 square feet.

What is R 5 zoning in NYC? ›

R5 Zoning is considered “low density” residential zoning. It typically has homes with 1 or 2 families each or small multi family buildings. R5 zoning most commonly has attached homes. R5 zoning is found in The Bronx, Brooklyn, Queens, and Staten Island.

What does R3A mean? ›

What is an R3A Zoning District? Characteristic of many of the city's older neighborhoods, R3A zoning districts feature modest single- and two-family detached residences on zoning lots as narrow as 25 feet in width. The amount of required open space on residential lots in R3A districts is governed by yard requirements.

What is C2 3 zoning NYC? ›

The C2-3 Zoning District is primarily residential with commercial uses on the street level. The commercial uses are usually typical commercial uses for residential areas including retail, restaurants, and services for the day to day needs of a residential neighborhood.

What does R4 zoning mean in New York? ›

R4 Zoning is a residential zoning district in NYC that allows for one family and two family as well as small multifamily residential building. You can build detached, semi detached, and attached buildings in R4 Zoning.

References

Top Articles
Latest Posts
Article information

Author: Laurine Ryan

Last Updated:

Views: 5944

Rating: 4.7 / 5 (77 voted)

Reviews: 92% of readers found this page helpful

Author information

Name: Laurine Ryan

Birthday: 1994-12-23

Address: Suite 751 871 Lissette Throughway, West Kittie, NH 41603

Phone: +2366831109631

Job: Sales Producer

Hobby: Creative writing, Motor sports, Do it yourself, Skateboarding, Coffee roasting, Calligraphy, Stand-up comedy

Introduction: My name is Laurine Ryan, I am a adorable, fair, graceful, spotless, gorgeous, homely, cooperative person who loves writing and wants to share my knowledge and understanding with you.